Building components- internal wall - iwmxxi02b Source: Saint-Gobain Rigips Austria GesmbH
 
 


Cross-section of standard configuration
[Additional views]

Last update21.09.2017/hfa.plb
internal wall: solid wood construction, with dry lining

register of building materials used for this application, cross-section
(from outside to inside, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 25.0 gypsum plasterboards Rigips RF (2x12,5 mm) or  0,250  10  900  1,050   A2
 25.0 gypsum fibre board Rigidur H (2x12,5 mm)  0,350  19  1200  1,100   A1
*   Exchangeable layer          
 50.0 mineral wool [040; 18]   0,040  18  1,030   A1
*   cross laminated timber BBS   0,130  50  470  1,600   D
*   Exchangeable layer          
 50.0 mineral wool [040; 18]   0,040  18  1,030   A1
 25.0 gypsum plasterboards Rigips RF (2x12,5 mm) or  0,250  10  900  1,050   A2
 25.0 gypsum fibre board Rigidur H (2x12,5 mm)  0,350  19  1200  1,100   A1
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  B* D* E* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   70,0  75,0  70,0  265,0  BBS 3 layer
B/E=Lattung (60/60) auf Schwingbügel 
60        –  53(-7,-15)  -5,0    iwmxxi02b-00  
 
01   85,0  75,0  85,0  295,0  BBS 3 layer
B/E=resilient channel 
60        –  68(-4,-12)  3,8    iwmxxi02b-01  
 
02   70,0  100,0  70,0  290,0  BBS 5 layer
B/E=Lattung (60/60) auf Schwingbügel 
90        –  53(-7,-15)  -0,8    iwmxxi02b-02  
 
03   85,0  100,0  85,0  320,0  BBS 5 layer
B/E=resilient channel 
90        –  68(-4,-12)  7,9    iwmxxi02b-03