Building components- intermediate floor - gdrnxa04a
 
 


Cross-section of standard configuration
[Additional views]

Last update14.11.2017/hfa.plb
intermediate floor: timber frame construction, suspended, wet, without filling

register of building materials used for this application, cross-section
(from top to bottom, dimensions in mm)

  Thickness Building material  λ   μ min - max   ρ   c  Reaction to fire
EN
 50.0 anhydrite screed or cement screed  0,700  10  2200  1,300   A1
  plastic separation layer   0,200  100000  1400  1,400   E
*   Exchangeable layer          
 19.0 particleboard   0,130  50 - 100  700  1,700   D
*   finger-jointed solid construction timber (80/..; e=*)  0,120  50  450  1,600   D
*   Insulation material            
 24.0 spruce wood cladding with spacing of cladding boards(24/100); a=400  0,120  50  450  1,600   D
 27.0 resilient channel (placed between open formwork)           
 12.5 gypsum plasterboards with improved properties at high temperatures (fire) or  0,250  10  800  1,050   A2
 12.5 gypsum fibre board   0,320  21  1000  1,100   A2
   
               
  Variations of building components

No. Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass HTMLPDF
  C* E* F* Σ   REI U [W/(m²K)] mw,B,A [kg/m²] Diffusion Ln,w(Cl) Rw(C,Ctr) OI3Kon m [kg/m²]   
00   30,0  220,0  100,0  358,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,27  18,5  adequate  52(0)  66(-1,-6)  4,3  144,0   gdrnxa04a-00  
F = glass wool [0,0040; R=16]
01   30,0  200,0  100,0  338,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,27  18,5  adequate  53(0)  66(-2,-7)  4,2  142,7   gdrnxa04a-01  
F = glass wool [0,0040; R=16]
02   30,0  240,0  100,0  378,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,27  18,5  adequate  51(0)  67(-1,-6)  10,2  145,3   gdrnxa04a-02  
F = glass wool [0,0040; R=16]
03   30,0  220,0  100,0  358,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,25  18,3  adequate  52(0)  66(-1,-6)  16,6  147,0   gdrnxa04a-03  
F = glass wool [0,0035; R=50]
04   30,0  220,0  100,0  358,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,27  18,5  adequate  52(0)  66(-1,-6)  5,5  145,5   gdrnxa04a-04  
F = mineral wool [0,038; R=33]
05   30,0  220,0  100,0  358,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,27  18,5  adequate  52(0)  66(-1,-6)  0,1  147,4   gdrnxa04a-05  
F = cellulose fibre [040; E]
06   30,0  220,0  100,0  358,5  e=625;
C=impact sound absorbing subflooring MW-T 
30  0,28  18,7  adequate  52(0)  66(-1,-6)  -0,1  144,0   gdrnxa04a-06  
F = sheep wool [0,041; R=16]
07   30,0  220,0  100,0  358,5  e=625;
C=impact sound absorbing subflooring EPS-T 
30  0,28  18,5  adequate  55(-1)  66(-2,-7)  -1,9  142,3   gdrnxa04a-07  
F = glass wool [0,0040; R=16]
08   30,0  220,0  100,0  358,5  e=400;
C=impact sound absorbing subflooring MW-T 
30  0,28  20,0  adequate  55(0)  63(-2,-7)  4,2  151,8   gdrnxa04a-08  
F = glass wool [0,0040; R=16]
09   30,0  220,0  100,0  358,0  e=625;
C=Polystyrene EPS-W [0,041] 
30  0,28  18,5  adequate  60(-1)  63(-3,-8)  2,0  142,4   gdrnxa04a-09  
F = glass wool [0,0040; R=16]